
Screen High Flux Liquid Handing System is to partition single nucleic acid template into separate reaction chambers and performs a single molecule quantification by PCR amplification and fluorescence signal detection. The digital PCR technology does not reply on neither Ct values nor standard calibration curves, and has extremely high sensitivity, precision, and excellent repeatability. It is an absolute quantitative analysis technology that transcends real-time PCR.
7L Adherent Cell Bioreactor
Bailun’s 7L Adherent Cell Bioreactor is designed for laboratory-scale adherent cell culture and advanced bioprocess development. The system provides a stable and low shear environment for sensitive adherent cells, supporting high cell viability and efficient cell expansion.
The bioreactor is ideal for vaccine production, stem cell cultivation, viral vector production, regenerative medicine research, and cell therapy process development.
Applications of 7L Adherent Cell Bioreactor
The system is widely used in:
HEK293 Cell Culture
Vero Cell Culture
BHK-21 Cell Culture
MDCK Cell Culture
MSC Stem Cell Expansion
Fibroblast Cell Culture
Hybridoma Cell Culture
Vaccine Development
Viral Vector Production
Cell Therapy Research
Regenerative Medicine
Tissue Engineering Research
Microcarrier Cell Culture
Biopharmaceutical Process Development
Suitable for biotechnology companies, pharmaceutical laboratories, universities, CDMO facilities, and research institutes.
Key Features of Bailun Adherent Cell Bioreactor
High-quality borosilicate glass vessel
Low shear agitation technology
Microcarrier culture compatible
Precise pH and dissolved oxygen control
Real-time monitoring and data recording
Gentle mixing for sensitive adherent cells
Compact laboratory bench-top design
PLC touchscreen control system
Modular and scalable configuration
High cell viability performance
Optimized Environment for Adherent Cell Culture
The system is specifically designed for sensitive adherent cell cultivation.
Features include:
Low turbulence agitation system
Stable dissolved oxygen control
Precise temperature regulation
CO₂ and multi-gas mixing control
Foam control system
Nutrient feeding optimization
Shear stress reduction design
Surface attachment optimization
These functions help improve cell attachment efficiency, cell growth, and process consistency.
Microcarrier Culture Support
The 7L Adherent Cell Bioreactor supports microcarrier-based cultivation for high-density adherent cell expansion.
Advantages include:
Increased cell growth surface area
Improved culture scalability
High-density cell production
Reduced manual operation
Better process reproducibility
Suitable for large-scale adherent cell process development.
Supported Adherent Cell Types
The system supports various adherent mammalian cell lines, including:
HEK293 Cells
Vero Cells
BHK-21 Cells
MDCK Cells
Mesenchymal Stem Cells (MSC)
Fibroblast Cells
Hybridoma Cells
Suitable for both research and biopharmaceutical production applications.
Advanced Automation & Intelligent Control
The bioreactor supports intelligent laboratory automation and precise process control.
Functions include:
Automatic pH control
Automatic dissolved oxygen control
Agitation speed control
Temperature control
Gas flow control
Feeding strategy automation
Real-time trend display
Historical data storage
Alarm and safety protection system
Optional Siemens PLC and SCADA software are available.
Designed for Process Development & Scale-Up
The 7L system supports process optimization and scale-up verification before pilot production.
Researchers can:
Optimize adherent cell culture conditions
Improve microcarrier performance
Compare feeding strategies
Validate scale-up feasibility
Reduce industrial production risks
The system can be integrated into larger pilot and industrial cell culture workflows.
Flexible Configuration Options
Bailun provides customized configurations according to different adherent cell culture applications.
Optional configurations include:
Mass flow controller
Exhaust gas analysis
Peristaltic feeding pumps
ORP sensor
Foam sensor
Turbidity sensor
Biomass sensor
Remote monitoring system
Multi-gas mixing system
Perfusion culture module
Available Adherent Cell Bioreactor Configurations
Bailun offers multiple adherent cell bioreactor configurations:
Glass adherent cell bioreactor
Stainless steel cell culture bioreactor
Microcarrier bioreactor
Single-use adherent cell bioreactor
Perfusion cell culture bioreactor
Parallel cell culture bioreactor
Working volumes are available from 2L to 200L.
Why Choose Bailun Adherent Cell Bioreactor
Professional bioprocess equipment manufacturer
Strong customization capability
Stable and reliable control system
Low shear adherent cell culture design
Scalable from lab to pilot production
Competitive pricing
Global technical support
Experience in cell therapy and biopharmaceutical systems
Technical Specifications
Parameter | Specification |
|---|---|
Total Volume | 7L |
Vessel Material | Borosilicate Glass |
Control System | PLC , Touchscreen |
Temperature Control | Automatic |
pH Control | Automatic |
DO Control | Automatic |
Agitation Type | Low Shear Mechanical Agitation |
Sterilization | Autoclavable |
Aeration | Multi-gas Mixing, O2 / N2 / CO2 / Air |
Feeding System | Peristaltic Pump |
Optional Configurations
Remote control
Mass flow meter
Gas inlet
Exhaust gas analysis
Level sensor
ORP sensor
Foam sensor
Glucose detection
Variable speed pump
Siemens touchscreen
SCADA software
Data export function
FAQ
What is an adherent cell bioreactor?
An adherent cell bioreactor is a controlled cultivation system designed for growing adherent mammalian cells that require attachment surfaces for growth.
Why use microcarriers for adherent cell culture?
Microcarriers provide a large surface area for adherent cells, allowing high-density cultivation and scalable production.
Which cells can be cultured in this bioreactor?
The system supports HEK293 cells, Vero cells, BHK-21 cells, MDCK cells, MSC stem cells, fibroblast cells, and other adherent mammalian cells.
What is the advantage of low shear agitation?
Low shear agitation minimizes cell damage and improves cell attachment and viability during cultivation.
Can the system support stem cell culture?
Yes, the system is suitable for mesenchymal stem cell (MSC) cultivation and expansion applications.
Is the bioreactor scalable?
Yes, the system is designed for process optimization and scale-up studies before pilot-scale production.
Can the system be customized?
Yes, Bailun provides customized vessel configurations, automation systems, gas control systems, and optional sensors according to customer requirements.
Request a Quote
Looking for a reliable adherent cell bioreactor solution?
Contact Bailun today for:
Customized bioreactor solution
Technical consultation
Detailed quotation
Global shipping and technical support


